6.1 DB Interface Function
6.1.2 Job execution procedure
6
FUNCTIONS
6.1.2 Job execution procedure
The following shows the job execution procedure.
Figure 6.2 Job execution procedure
Start
Working
Enabled
When [Handshake operation] is selected for Trigger
conditions, tag component values are read out from the
programmable controller CPU.
No job is executed while the function is stopped.
Activate the MES interface function.
Stopped
The job is not executed when it is disabled.
Enable the job.
Disabled
(To the next page)
Is the MES interface function
working?
Is the job enabled?
Job execution starts when trigger conditions are met.
Is the [Execute
program before action.] box
checked?
Checked
Not checked
The program in the application server computer is
executed before execution of the first action.
• Section 7.13.1 Checking the operation status of the
MES interface function
Section 7.13.2 Manipulating the operation status of the
MES interface function
• Section 7.13.4 Changing the job status
• Chapter 9 XML MESSAGE FORMAT
• Section 6.1.4 Trigger monitoring function
• Section 7.10.2 Setting items in Trigger
conditions
• Section 6.1.9 Program execution function
• Section 7.10.3 Setting items in Program execution